Choke: Set the choke control in the choke position.
When the engine is started with the choke in either the
choke or start throttle positions the cutting attachment will
start to rotate immediately.
Hold the body of the machine on the ground using your left hand
(CAUTION! Not with your foot!). Grip the starter handle, slowly
pull out the cord with your right hand until you feel some esistance
(the starter pawls grip), now quickly and powerfully pull the cord.
Never twist the starter cord around your hand.
Repeat pulling the cord until the engine starts. When the engine
starts. return choke control to run position and apply full throttle;
the throttle will automatically disengage from the start setting.
CAUTION! Do not pull the starter cord all the way out and do not
let go of the starter handle when the cord is fully extended. This
can damage the machine.
WARNING
CAUTION! Do not put any part of your body in marked area.
Contact can result in burns to the skin, or electrical shock if the
spark plug cap has been damaged. Always use gloves. Do not
use a machine with damaged spark plug cap.
Stopping
Stop the engine by switching off the ignition.
CAUTION! The stop switch automatically returns to the start
position. In order to prevent unintentional starting, the spark plug
cap must be removed from the spark plug when assembling,
checking and/or performing maintenance.