11
Storage
Trouble Shooting Guide
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel drain and fill with correct fuel
fuel filter fuel filter is clogged clean
carburetor adjustment screw out of normal range adjust to normal range
sparking (no spark) is fouled/wet clean/dry
plug gap is incorrect correct (GAP: 0.6~0.7mm)
spark plug
spark plug disconnected retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel or staled fuel drain and fill with correct fuel
carburetor adjustment screw out of normal range adjust to normal range
muffler, cylinder (exhaust port) carbon is built-up wipe away
air cleaner clogged with dust wash
cylinder fin, fan cover clogged with dust clean
When your unit seems to need further service, please consult with the G.E.B.E.
Aged fuel is one of major causes of engine starting failure. Before storing the unit, empt
the fuel tank and run the engine until it uses all the fuel left in the fuel line and the
carburetor. Store the unit indoor taking necessary measures for rust prevention.