39
4. Service Guide
Two stage dry element (Pre-filter + Paper filter) EBZ80 Series
Loosen the knob bolts then remove the element
(pre-filter + paper filter).
4-30 Element Cleaning
Element and pre-filter rinsing All Models
Rinse the element carefully with warm water diluted
detergent or washing oil.
Confirm that no deformity, damage or
deterioration (if touched, element will
crumble) exists.
If necessary replace it with a new one.
After rinsing it, tighten squeeze the element to
remove moisture.
For a HB23 series and HBZ26 series element or a
EB70 series and EBZ71/ 80 series pre-filter, dry it
after rinsing and then install it.
Caution for element installation EB4300/ 6200, EBZ4800, EBZ51 Series
The half-wet urethane element should be moistened
with 2-cycle engine oil, softly squeezed, then installed.
Excessive oil adhesion will cause filter
clogging.
Never moisten pre-filter (EB70 series and
EBZ71/80 series) with engine oil.
If engine oil adheres to the filter, the paper
layer will not function.
Two stage dry paper filter cleaning EB70 Series, EBZ71/ 80 Series
Blow compressed air from inside/outside of the filter
along the filter element's pleats.
Never beat or hit the filter.
CAUTION
CAUTION
CAUTION
Cover
Pre-filter
Knob Bolts
Case
Paper Filter
Warm water diluted
detergent or washing oil
2-cycle engine oil
Page view 46